Wastewater/ CALCULATOR

Sump pump battery runtime

Estimate outage runtime from usable battery energy, pump duty cycle and standby load.

Use watt-hours from the battery specification.
Reserve capacity for battery life and low-voltage cutoff.
Include inverter and wiring losses.
Use measured running input; starting power is checked separately.
Use a wet-weather observation or conservative scenario.
Include inverter idle draw, controls and alarms.
Usable delivered energy

844.80 Wh

Pump duty cycle

16.67 %

Average pump demand

83.33 W

Average total demand

91.33 W

Estimated outage runtime

9.25 h

Energy used each hour

91.33 Wh/h

Interpretation:The energy-only estimate is 9.25 hours at an average load of 91.33 W. Confirm motor starting surge and test the complete backup system.

The observed duty cycle remains constant and the power source can supply motor starting surge. Capacity falls with age, temperature and high discharge rate. This energy estimate does not verify inverter surge, transfer controls, alarms or safe battery installation.